Vickers Vane Pumps and Double Vane Pumps

   Wechat: +86 13728707767
   Whats app: +86 13728707767
   E-mail: hyd-sales2009@outlook.com

Description

Vickers Vane Pumps and Double Vane Pumps – Specifications & Models

1. Overview

Vickers, a renowned brand under Eaton, offers a comprehensive range of fixed displacement vane pumps, including single vane pumps and double vane pumps. These pumps are widely applied in industrial and mobile hydraulic systems, featuring balanced vane construction, high efficiency, low noise, and long service life. The main product series include V10/V20/V2010/V2020 and V/VQ series, covering various flow and pressure requirements.

2. Single Vane Pumps

2.1 V10/V20 Series

2.1.1 Model Nomenclature

Typical model format: (F3-) V10 – 1P5S – 1C20L
  • F3: Viton seals (omitted if not required)
  • Series Designation: V10 (small flow) / V20 (medium flow)
  • Installation: L = 2-bolt flange
  • Inlet Connection: P/S/M (V10: 1” NPT / 1.3125-12 UNF-2B / M33×2-7H; V20: 1.25” NPT / 1.625-12 UNF-2B / M42×2-7H)
  • Flow Code: Corresponding to flow rate at 1200 rpm and 6.9 bar (see Table 1)
  • Outlet Connection: P/S/R/M (V10: 1/2” NPT / 0.75-16 UNF-2B / M20×1.5-7H; V20: 3/4” NPT / 1.0625-12 UNF-2B / M27×2-7H)
  • Shaft Type: 1 = straight key; 11 = spline
  • Outlet Position: A = opposite inlet; B = 90° CCW from inlet; C = same side as inlet; D = 90° CW from inlet (viewed from cover end)
  • Rotation: Clockwise (omitted); Counterclockwise (marked)

2.1.2 Technical Specifications

Series
Flow Code
Flow Rate (USGPM) @1200 rpm
Geometric Displacement (ml/r)
Max Speed (rpm)
Max Pressure (MPa)
Weight (kg)
V10
1
3.3
20
1800
14
≈8.5
2
6.6
40
3
9.8
60
4
13.0
79
5
16.5
101
6
19.5
119
7
23.0
140
V20
6
19.5
119
1800
14
≈11.8
7
23.0
140
8
26.5
162
9
29.7
181
10
33.0
200
11
36.4
222
12
39.0
238

2.2 V/VQ Series

2.2.1 Model Nomenclature

Typical model format: (F3-) 25VQ21A(F)-1A20L
  • F3: Special fluid seal (omitted for standard petroleum-based fluids)
  • Series Designation: 20V/25V/35V/45V (industrial) / 20VQ/25VQ/35VQ/45VQ (mobile)
  • Displacement Code: Corresponding to displacement (see Table 2)
  • Pump Port Connection: A = SAE 4-bolt flange
  • Mounting Type: Omitted = flange mounting; F = foot mounting
  • Shaft Extension: 1 = straight shaft with key; 11 = spline shaft
  • Outlet Position: A/D = opposite inlet; B = 90° CCW; C = same side (viewed from cover end)
  • Rotation: L = counterclockwise; omitted = clockwise

2.2.2 Technical Specifications

Series
Displacement Code
Displacement (cm³/r)
Max Speed (rpm)
Max Pressure (MPa)
Weight (kg)
20V/20VQ
2-14
7.5-45
1800
14 (20V) / 21 (20VQ)
11.8
25V/25VQ
10-21
33-67
1800
17.5 (25V) / 21 (25VQ)
14.5
35V/35VQ
21-38
67-121
1800
17.5 (35V) / 21 (35VQ)
22.7
45V/45VQ
42-60
138-193
1800
17.5 (45V) / 21 (45VQ)
34

3. Double Vane Pumps

3.1 V2010/V2020 Series

3.1.1 Model Nomenclature

Typical model format: (F3-) V2010 – 1F13S3S – 1CC10L
  • F3: Viton seals (omitted if not required)
  • Series Designation: V2010 (V20 shaft-end + V10 cover-end) / V2020 (V20 shaft-end + V20 cover-end)
  • Installation: 1 = 2-bolt flange
  • Inlet Connection: F = 4-bolt flange
  • Flow Code (Shaft-end Pump): Corresponding to V20 flow rate (6-13)
  • Outlet 1 Connection: S = 1.062-12 UN (V2010/V2020)
  • Flow Code (Cover-end Pump): V2010 (1-7, V10 flow); V2020 (6-13, V20 flow)
  • Outlet 2 Connection: S = 0.75-12 UN (V2010); 1.062-12 UN (V2020)
  • Shaft Type: 1 = straight key; 11 = spline
  • Outlet Positions: CC = Custom position (viewed from cover end)

3.1.2 Technical Specifications

Series
Shaft-end Pump Flow (USGPM)
Cover-end Pump Flow (USGPM)
Max Speed (rpm)
Max Pressure (MPa)
Feature
V2010
19.5-42.5
3.3-23.0
1800
14
Mixed flow rates for dual circuits
V2020
19.5-42.5
19.5-42.5
1800
14
Equal flow rates for high-volume demand

3.2 V Series Double Pumps

Combined by two single V-series pumps, model format: 2520V/3520V/3525V/4525V etc. (e.g., 4535V50A25-1AA22R). Key specifications are consistent with single V-series pumps, with max pressure up to 17 MPa and max speed 1800 rpm. Suitable for industrial systems requiring dual independent hydraulic circuits.

4. Core Features

  • Balanced Vane Design: Diametrically opposed inlet/outlet chambers balance radial loads, extending bearing life.
  • High Performance: Volumetric efficiency >90%, noise level as low as 62 dB(A), suitable for high-pressure operation.
  • Versatility: Compatible with petroleum-based oil and synthetic fire-resistant fluids; reversible rotation via internal part adjustment.
  • Compact Structure: Double pumps integrate two units in one housing, reducing installation space and simplifying drive system.

5. Applications

Industrial presses, aerial booms, plastic injection molding machines, material handling equipment, heavy-duty trucks, and complex hydraulic power units.

Hydraulic pump manufacturer

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Vickers Vane Pumps and Double Vane Pumps”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.