news

YUKEN EHDG series high frequency response proportional valve

YUKEN EHDG Series High-Response Proportional Valve Model and Parameters

1. Model Designation

The complete model format of YUKEN EHDG series high-response proportional valve is: EHDG-01V-B-S-1-PNT15M10-50. Each segment of the model has a specific meaning, as detailed below:

Model SegmentDescription
F-Special seals for phosphate ester type fluid (omit if not required)
EHDGProportional electro-hydraulic pilot relief valve (series code)
-01Valve size
VVent control of relief valve (omit if not required)
-B/-C/-HPressure adjustment range: B (0.5-6.9 MPa / 70-1000 psi), C (1-15.7 MPa / 145-2275 psi), H (1.2-24.5 MPa / 175-3550 psi)
-S/-LControl type: S (open-loop with sensor), L (closed-loop)
-1With safety valve (omit if without safety valve)
-PNP-line orifice (without orifice if omitted, standard type)
T15/T13/T11T-line orifice: T15 (for B range), T13 (for C range), T11 (for H range)
M10Standard orifice for P-B line
-50Design number

2. Technical Specifications (Taking EHDG-01 as an Example)

Specification ItemValue
Maximum Operating Pressure24.5 MPa (3550 psi)
Maximum Flow Rate2 L/min (0.53 U.S. gpm)
Minimum Flow Rate0.3 L/min (0.08 U.S. gpm)
Hysteresis1% or less (3% or less for open-loop type; value in parentheses is for closed-loop type)
Repeatability1% or less (tested under conditions similar to original testing)
Frequency ResponseB: 10 Hz (-90 degree), C: 10 Hz (-90 degree), H: 12 Hz (-90 degree)
Supply Electric Power24 V DC (21 to 28 V DC, including ripple)
Maximum Power Input28 W
Input SignalB: 6.9 MPa (1000 psi) / 5 V DC; C: 15.7 MPa (2275 psi) / 5 V DC; H: 24.5 MPa (3550 psi) / 5 V DC
Input Impedance10 kΩ
Alarm Signal Output (Open Collector)Voltage: Max. 30 V DC; Current: Max. 40 mA
Pressure Signal OutputB: 5 V DC / 6.9 MPa (1000 psi); C: 5 V DC / 15.7 MPa (2275 psi); H: 5 V DC / 24.5 MPa (3550 psi)
Ambient Temperature0 – 50 °C (32 – 122 °F) (with circulated air)
Coil Resistance10 Ω

3. Product Overview

YUKEN EHDG series is a type of proportional electro-hydraulic pilot relief valve, specifically designed for hydraulic systems that require small flow and continuous pressure regulation. It can also be used as a pilot control unit for other proportional valves. The valve features high response speed, stable performance, and precise pressure control, making it suitable for various industrial hydraulic applications that demand high control accuracy.