Company News

YUKEN 50T series quantitative vane pump model and parameters

I. Series Overview

The YUKEN 50T series is a low-noise, pressure-balanced structure fixed displacement single-stage vane pump with low shaft load and long service life. It is widely used in lubrication systems, cooling systems, light-load hydraulic circuits, precision machine tools and other scenarios. It can be used as a low-pressure vane pump in high-pressure systems, and can also be composed of double pumps (such as 5050T, 50150T) or combined pumps (such as 5050ST, 50150ST).

II. Model Nomenclature Rules

Complete model example:50T-26-F-RL-30
Position
Code
Meaning
1
50T
Series name (fixed displacement single-stage vane pump)
2
26
Nominal displacement (cm³/rev)
3
F/L
Mounting type: F = Flange type, L = Foot type
4
RL/RR/LR/LL
Oil discharge port direction + rotation direction (viewed from the shaft end) RL = Left oil discharge + clockwise (standard), RR = Right oil discharge + clockwise LR = Left oil discharge + counterclockwise, LL = Right oil discharge + counterclockwise
5
30/3T
Pressure level / specification code (30 is standard type)

III. Complete Model List

The displacement range of the 50T series single-stage fixed displacement vane pump is 6.8-38.9 cm³/rev, and the specific models are as follows:
  • 50T-07 (6.8 cm³/rev)
  • 50T-12 (11.6 cm³/rev)
  • 50T-14 (13.7 cm³/rev)
  • 50T-17 (16.5 cm³/rev)
  • 50T-20 (19.8 cm³/rev)
  • 50T-23 (22.9 cm³/rev)
  • 50T-26 (25.9 cm³/rev)
  • 50T-30 (29.6 cm³/rev)
  • 50T-36 (36.0 cm³/rev)
  • 50T-39 (38.9 cm³/rev)

IV. Detailed Technical Parameters Table

Model
Theoretical Displacement (cm³/rev)
Rated Pressure (MPa)
Maximum Pressure (MPa)
Speed Range (r/min)
Piping Size (Outlet / Inlet)
Weight (kg)
50T-07
6.8
7.0
9.0
800-2000
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-12
11.6
7.0
9.0
600-2000
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-14
13.7
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-17
16.5
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-20
19.8
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-23
22.9
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-26
25.9
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-30
29.6
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-36
36.0
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0
50T-39
38.9
7.0
9.0
600-1800
3/4″ / 1″
Foot type: 10.5, Flange type: 9.0

V. Other Key Parameters and Features

  1. Applicable Medium: ISO VG 15-100 hydraulic oil, ISO VG 32-68 viscosity grade is recommended
  2. Filtration Precision: 10μm is recommended to avoid vane wear
  3. Operating Temperature: 40-60℃, forced cooling is required when exceeding 70℃
  4. Noise Characteristics: Stable operation, noise lower than 65 dB (A)
  5. Structural Features: Pressure-balanced design reduces shaft load and improves efficiency and service life

VI. Double Pump Models

The 50T series can be combined with the same series or other series to form a double pump. Common models:
  • 5050T: Combination of two 50T series pumps
  • 50150T: Combination of 50T series + 150T series pumps