Home » Product » VDC-12A(B)-2A3-2A*20/35 Nachi Double vane Pump

VDC-12A(B)-2A3-2A*20/35 Nachi Double vane Pump

   VDC Series:VDC-1A/B; VDC-2A/B; VDC-3A/B 
   Whats app: +86 13728707767
   E-mail: hyd-sales2009@outlook.com
We are a professional manufacturer of hydraulic pumps, offering a complete range of products. Inquiries are welcome! (#^.^#)

Description

Nachi Double Vane Pump VDC-12A-2A3-2A*20/35 & VDC-12B-2A3-2A*20/35 Specifications

Nachi VDC-12A-2A3-2A*20/35 and VDC-12B-2A3-2A*20/35 are high-performance double vane pumps (twin vane pumps) designed for industrial hydraulic systems, integrating two vane pump units into one compact structure. Featured with stable operation, high pressure resistance, low noise, space-saving design and enhanced dual constant discharge performance, these pumps are ideal for hydraulic systems requiring dual-path, synchronous and stable hydraulic power output. This document provides detailed technical parameters, model interpretation, key features and application scope, helping users quickly understand, select and apply the product. Suitable for machinery, automation, engineering equipment, plastic machinery and other fields requiring reliable dual-path hydraulic power with high pressure and stable flow demand.

Model Interpretation

The model codes of Nachi VDC series double vane pumps have clear and standardized meanings, which can help users quickly identify product specifications and avoid selection errors:
  • VDC: Series name, representing Nachi high-pressure variable displacement vane pump, widely used in industrial high-pressure hydraulic systems.
  • 12: Double pump identifier, indicating that the product is a twin (double) vane pump, integrating two independent vane pump units with optimized structure, which has higher flow stability and pressure-bearing capacity compared with the VDC-11 series double vane pump.
  • A/B: Mounting method (A: Foot type mounting, sub plate type, sub plate not included; B: Flange mounting optional, suitable for different installation space and application scenarios).
  • 2: Pump size, indicating the basic structural size of each single vane pump unit in the double pump (matched with the VDC-2 series single pump size, optimized for flow output).
  • A: Ring size, corresponding to the matching size of the pump ring, ensuring stable operation and pressure resistance of the pump under high-flow working conditions.
  • 3: Pressure adjustment range, corresponding to the high-pressure regulation specification for the VDC-12 series double vane pump, suitable for medium and high-pressure hydraulic system requirements.
  • 2A: Flow characteristics, meaning dual constant discharge type, ensuring synchronous and stable flow output of both two pump units, with higher flow consistency, perfectly matching the working demand of dual-path hydraulic systems that require synchronous operation and stable power supply.
  • *20/35: Design and matching code, 20 represents the basic design number of the pump, 35 represents the matching specification of the pressure control component, ensuring the pump’s pressure stability and control precision under high-flow and high-pressure conditions.

Detailed Technical Parameters

Parameter Item
Nachi VDC-12A-2A3-2A*20/35
Nachi VDC-12B-2A3-2A*20/35
Displacement per unit (in³/rev)
2.3 (each pump unit)
2.3 (each pump unit)
Total Displacement (in³/rev)
4.6 (two pump units combined)
4.6 (two pump units combined)
No-Load Discharge Rate (gpm) @ 1500 min⁻¹ (per unit)
15.3
15.3
Total No-Load Discharge Rate (gpm) @ 1500 min⁻¹
30.6
30.6
No-Load Discharge Rate (gpm) @ 1800 min⁻¹ (per unit)
18.4
18.4
Total No-Load Discharge Rate (gpm) @ 1800 min⁻¹
36.8
36.8
Pressure Adjustment Range (psi)
290 – 1800
290 – 1800
Pressure Adjustment Range (kgf/cm²)
20.4 – 128.6
20.4 – 128.6
Allowable Peak Pressure (psi)
3000
3000
Allowable Peak Pressure (kgf/cm²)
214.3
214.3
Shaft Speed Range (min⁻¹)
800 – 1800
800 – 1800
Weight (lbs)
108
111
Weight (kg)
49.0
50.4
Mounting Method
Foot type mounting (Sub plate type, sub plate not included)
Flange mounting optional
Flow Characteristics
Dual constant discharge type (dual units synchronous output, high flow consistency)
Dual constant discharge type (dual units synchronous output, high flow consistency)
Design Number
20
20
Rotation Direction
Right from shaft end (both units synchronous rotation)
Right from shaft end (both units synchronous rotation)
Material
High-strength reinforced cast iron (enhanced for double pump pressure-bearing, wear resistance and high-flow adaptability)
High-strength reinforced cast iron (enhanced for double pump pressure-bearing, wear resistance and high-flow adaptability)
Pressure Control Precision
±0.3MPa (excellent level), pressure fluctuation ≤0.1MPa
±0.3MPa (excellent level), pressure fluctuation ≤0.1MPa
Operation Noise (dB @ 1m)
≤55dB, low noise design
≤55dB, low noise design

Key Features

  • Dual-Path Synchronous Hydraulic Output: Integrates two independent vane pump units with optimized structure, providing stable dual-path hydraulic power output that can be used synchronously or independently. The dual constant discharge type (2A) ensures high flow consistency of the two units, perfectly adapting to the working demand of dual-path hydraulic systems that require synchronous operation, and saving installation space compared with two single pumps.
  • High Pressure Stability & High-Flow Adaptability: With allowable peak pressure up to 3000 psi (214.3 kgf/cm²) and pressure adjustment range of 290-1800 psi, equipped with high-precision pressure control components (matching code 35), pressure control precision reaches ±0.3MPa, pressure fluctuation ≤0.1MPa. Optimized pump size and structure enhance high-flow adaptability, suitable for medium and high-pressure systems with high flow demand.
  • Stable & Quiet Operation: Adopts 3-point ring support system and optimized structural design, combined with precision machining and noise reduction technology, operation noise is ≤55dB (1m distance), minimizing vibration and noise, suitable for precision machinery and indoor working scenarios.
  • High Efficiency & Durability: Innovative mechanical design reduces power loss and improves overall system efficiency; high-strength reinforced cast iron material (enhanced for high-flow and high-pressure working conditions) enhances pressure-bearing capacity and wear resistance, ensuring long service life even under long-term continuous operation of double pump units.
  • Easy Installation & Maintenance: Compact integrated structure, foot/flange optional mounting methods, adapting to different installation spaces; pressure and flow adjustment mechanisms of the two pump units are concentrated on the same side, simplifying maintenance and handling, reducing equipment downtime.
  • Strong Adaptability: Wide shaft speed range (800-1800 min⁻¹), suitable for different power matching requirements; dual constant discharge type design ensures stable and consistent flow output of each pump unit, adapting to various industrial hydraulic system scenarios that require dual-path synchronous power supply.

Application Scope

Nachi VDC-12A-2A3-2A*20/35 and VDC-12B-2A3-2A*20/35 double vane pumps are widely used in various industrial fields requiring dual-path high-pressure and high-flow hydraulic power, including large-scale injection molding machines, heavy-duty hydraulic presses, engineering construction machinery, high-precision automated production lines, plastic machinery, metallurgical equipment, and complex hydraulic systems that need dual-path synchronous power supply. With compact structure, stable dual-path synchronous output, high pressure resistance, high-flow adaptability and low noise, they are an ideal choice for medium and high-pressure dual-path hydraulic systems with strict requirements on space, efficiency, flow consistency and stability.

Note

1. The parameters are standard values; actual performance may vary slightly according to the working environment, hydraulic oil quality and operating conditions.
2. It is recommended to use hydraulic oil that meets Nachi’s high-pressure specifications, and control the oil temperature within the range of -10℃ to +70℃ to ensure the service life and performance of the pump, avoiding damage caused by inappropriate oil quality, viscosity or impurity content.
3. The two pump units adopt synchronous rotation design; do not adjust the rotation direction arbitrarily to avoid mechanical failure. For more detailed installation, debugging and maintenance guidelines, please refer to the official Nachi VDC series double vane pump product manual.
4. The pump is equipped with pressure control components matching code 35, which can be adjusted according to the actual system pressure requirements, and it is not recommended to exceed the allowable peak pressure for long-term operation.
Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.