A16-FR04BK-32 YUKEN variable displacement piston pump
YUKEN piston pump series: A series, AR series, ARL1 series, A3H series, A3HG series, A7H series.
Whats app: +86 13728707767
E-mail: hyd-sales2009@outlook.com
We are a professional manufacturer of hydraulic pumps, offering a complete range of products. Inquiries are welcome! (#^.^#)
Parameter Specification of YUKEN Piston Pump A16-FR04BK-32
1. Model Interpretation
-
A16: Series identifier + geometric displacement, indicating the “A” series piston pump with a geometric displacement of 16 cm³/rev (0.98 cu.in./rev)
-
F: Mounting type, flange mounting
-
R: Rotation direction, clockwise rotation (viewed from the shaft end, standard configuration)
-
04: Control mode, remote pressure control (external pressure signal control)
-
B: Pressure adjustment range, 3.5 – 21 MPa (36 – 305 psi)
-
K: Shaft type, keyed shaft
-
32: Design number, corresponding to the standard design specification of the pump
2. Core Technical Parameters
|
Parameter Name
|
Specification
|
Unit
|
|
Geometric Displacement
|
16 (0.98)
|
cm³/rev (cu.in./rev)
|
|
Minimum Adjustable Flow
|
1.0 (0.06)
|
cm³/rev (cu.in./rev)
|
|
Rated Operating Pressure
|
25 (3630)
|
MPa (psi)
|
|
Maximum Intermittent Pressure
|
28 (4060)
|
MPa (psi)
|
|
Shaft Speed Range
|
600 – 1800
|
r/min
|
|
Flow Adjustment Range
|
0.5 – 28.8 (0.13 – 7.6)
|
L/min (U.S. gpm)
|
|
Minimum Pressure Required for Flow Adjustment
|
3.5 (510)
|
MPa (psi)
|
|
Differential Pressure (Discharge Pressure – Load Pressure)
|
0.22 – 0.37 (30 – 55)
|
MPa (psi)
|
3. Installation & Structural Parameters
-
Mounting Type: Flange mounting (code “F”)
-
Rotation Direction: Clockwise (viewed from the shaft end, code “R”), standard configuration
-
Shaft Type: Keyed shaft (code “K”)
-
Approximate Weight (Flange Mounting): 12 kg (26.5 lbs)
-
Port Specification: The suction port (S) has an inner diameter of 25 mm, and the discharge port (P) has an inner diameter of 18 mm; the port connection complies with SAE J518 standard (4 bolts)
-
Drain Pipe Requirement: A separate drain pipe should be installed for each side of the pump, with a pipe inner diameter of not less than 10 mm (3/8 inch, inner diameter ≥ 8 mm)
4. Fluid & Environmental Parameters
-
Applicable Fluid: Petroleum-based hydraulic oil equivalent to ISO VG 32 or ISO VG 46
-
Fluid Viscosity Range: 20 – 400 mm²/s (20 – 400 cSt)
-
Operating Temperature Range: 0 – 60 °C
-
Fluid Contamination Control: The contamination level should be within NAS 10
-
Suction Pressure Requirement: -16.7 kPa ~ 50 kPa (-125 mmHg ~ +0.5 kgf/cm²)
5. Performance Characteristics
-
Efficiency: At 16 MPa (2320 psi) and 1800 r/min, the volumetric efficiency exceeds 98% and the overall efficiency exceeds 90%.
-
Step Response: The step response time (0 to maximum flow) is 5 ms, and the hysteresis is 2% or less (depending on the circuit and operating conditions).
-
Noise Performance: Advanced structural design ensures low noise operation, providing a quiet working environment.
-
Energy Saving: High overall efficiency effectively reduces power loss, minimizes oil temperature rise, and lowers the requirement for fuel tank capacity.
6. Safety & Usage Notes
-
When setting the pressure, ensure that the full cut-off pressure does not exceed the maximum intermittent pressure (28 MPa).
-
If the pump is operated above the rated pressure (25 MPa), the operating conditions are restricted: the intermittent time at maximum flow should not exceed 1/5 of one cycle time and 6 seconds simultaneously.
-
Avoid applying bending or radial loads to the pump shaft; the TIR of the drive shaft should not exceed 0.1 mm, and the angle deviation should not exceed 0.2°.
-
Ensure complete air bleeding of the pump and pipeline to avoid vibration caused by air entrapment.
-
When the pump is installed above the oil level, a foot valve should be installed in the suction pipeline, and the height from the suction port to the oil level should not exceed 1 m.

yuken Variable Displacement Piston Pumps
| A10-F-R-01-B-K-32 A10-FR07CS-12 A10-LR09DS-60 A100-FR01BS-60 A100-FR07CS-12 A100-LR09DS-60 A145-F-R-05EH-60 A145-FR01CK-32 A145-FR04BK-32 A145-LR01AS-60 A16-F-R-01-C-K-32 A16-FR01CK-32 A16-FR04BK-32 A16-LR01AS-60 A22-F-R-01-B-K-32 A22-FR01BS-60 A22-FR07CS-12 A22-LR09DS-60 A37-F-R-01-C-K-32 A37-FR01CK-32 A37-FR04BK-32 A37-LR01AS-60 A45-FR01BS-60 A45-FR07CS-12 A45-LR09DS-60 |
A56-FR01CK-32 A56-FR04BK-32 A56-LR01AS-60 A70-FR01BS-60 A70-FR07CS-12 A70-LR09DS-60 A90-FR01CK-32 A90-FR04BK-32 A90-LR01AS-60 AR16-FR01C-12 AR16-FR01C-22 AR16-FR01D-12 AR16-FR07C-22 AR16-LR01C-22 AR16-LR09C-22 AR22-FR01C-12 AR22-FR01C-22 AR22-FR01D-12 AR22-FR04C-22 AR22-LR01C-22 AR22-LR04C-22 AR37-FR01C-22 AR37-FR07C-22 AR37-LR01C-22 AR37-LR07C-22 |
ARL1-16-FR01C-22 ARL1-16-FR04C-22 ARL1-16-LR01C-22 ARL1-16-LR04C-22 ARL1-22-FR01C-22 ARL1-22-FR07C-22 ARL1-22-LR01C-22 ARL1-22-LR07C-22 ARL1-8-F-R-01-C-K-10 A7H180-FR01KK-10 A7H180-FR07KK-10 A7H180-FR09-11A4K-10 A7H180-LR01KK-10 A7H180-LR07KK-10 A3H100-FR01-11A4K-10 A3H100-FR07-11A4K-10 A3H100-FR09-11A4K-10 A3H116-FR01KK-10 A3H116-FR07KK-10 A3H145-FR01-11A4K-10 A3H145-FR01KK-10 A3H145-FR04KK-10 A3H145-FR07-11A4K-10 A3H145-FR09-11A4K-10 A3H16-FR01-11A4K-10 |
A3H16-FR01KK-10 A3H16-FR07-11A4K-10 A3H16-FR09-11A4K-10 A3H16-FR14KK-10 A3H16-LR01KK-10 A3H180-FR01-11A4K-10 A3H180-FR01KK-10 A3H180-FR07-11A4K-10 A3H180-FR07KK-10 A3H180-FR09-11A4K-10 A3H37-FR01-11A4K-10 A3H37-FR01KK-10 A3H37-FR07-11A4K-10 A3H37-FR07KK-10 A3H37-FR09-11A4K-10 A3H37-LR01KK-10 A3H56-FR01-11A4K-10 A3H56-FR01KK-10 A3H56-FR04KK-10 A3H56-FR07-11A4K-10 A3H56-FR09-11A4K-10 A3H56-LR01KK-10 A3H71-FR01-11A4K-10 A3H71-FR01KK-10 A3H71-FR07-11A4K-10 |
A3H71-FR07KK-10 A3H71-LR01KK-10 A3H90-FR01KK-10 A3H90-FR04KK-10 A3HG16-FR01KK-10 A3HG37-FR01KK-10 A3HG56-FR01KK-10 A3HG71-FR01KK-E1C-10 A3HG71-FR01KK-E1D-10 A3HG71-FR01KK-J1C-10 A3HG71-FR01KK-J1D-10 A3HG71-FR01KK-U1C-10 A3HG71-FR01KK-U1D-10 A3HG71-FR07KK-E1C-10 A3HG71-FR07KK-E1D-10 A3HG71-FR07KK-J1C-10 A3HG71-FR07KK-J1D-10 A3HG71-FR07KSP-E1C-10 A3HG71-FR07KSP-E1D-10 A3HG71-FR14KK-E1C-10 A3HG71-FR14KK-E1D-10 A3HG71-FR14KK-J1C-10 A3HG71-FR14KK-J1D-10 A3HG71-FR14KSP-E1C-10 A3HG71-FR14KSP-E1D-10 |
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.