Home » Product » A16-FR04BK-32 YUKEN variable displacement piston pump

A16-FR04BK-32 YUKEN variable displacement piston pump

YUKEN piston pump series: A series, AR series, ARL1 series, A3H series, A3HG series, A7H series.
   Whats app: +86 13728707767
   E-mail: hyd-sales2009@outlook.com
We are a professional manufacturer of hydraulic pumps, offering a complete range of products. Inquiries are welcome! (#^.^#)

Description

Parameter Specification of YUKEN Piston Pump A16-FR04BK-32

1. Model Interpretation

The model A16-FR04BK-32 is a variable displacement axial piston pump of YUKEN “A” series, and each code in the model has the following meaning:
  • A16: Series identifier + geometric displacement, indicating the “A” series piston pump with a geometric displacement of 16 cm³/rev (0.98 cu.in./rev)
  • F: Mounting type, flange mounting
  • R: Rotation direction, clockwise rotation (viewed from the shaft end, standard configuration)
  • 04: Control mode, remote pressure control (external pressure signal control)
  • B: Pressure adjustment range, 3.5 – 21 MPa (36 – 305 psi)
  • K: Shaft type, keyed shaft
  • 32: Design number, corresponding to the standard design specification of the pump

2. Core Technical Parameters

Parameter Name
Specification
Unit
Geometric Displacement
16 (0.98)
cm³/rev (cu.in./rev)
Minimum Adjustable Flow
1.0 (0.06)
cm³/rev (cu.in./rev)
Rated Operating Pressure
25 (3630)
MPa (psi)
Maximum Intermittent Pressure
28 (4060)
MPa (psi)
Shaft Speed Range
600 – 1800
r/min
Flow Adjustment Range
0.5 – 28.8 (0.13 – 7.6)
L/min (U.S. gpm)
Minimum Pressure Required for Flow Adjustment
3.5 (510)
MPa (psi)
Differential Pressure (Discharge Pressure – Load Pressure)
0.22 – 0.37 (30 – 55)
MPa (psi)

3. Installation & Structural Parameters

  • Mounting Type: Flange mounting (code “F”)
  • Rotation Direction: Clockwise (viewed from the shaft end, code “R”), standard configuration
  • Shaft Type: Keyed shaft (code “K”)
  • Approximate Weight (Flange Mounting): 12 kg (26.5 lbs)
  • Port Specification: The suction port (S) has an inner diameter of 25 mm, and the discharge port (P) has an inner diameter of 18 mm; the port connection complies with SAE J518 standard (4 bolts)
  • Drain Pipe Requirement: A separate drain pipe should be installed for each side of the pump, with a pipe inner diameter of not less than 10 mm (3/8 inch, inner diameter ≥ 8 mm)

4. Fluid & Environmental Parameters

  • Applicable Fluid: Petroleum-based hydraulic oil equivalent to ISO VG 32 or ISO VG 46
  • Fluid Viscosity Range: 20 – 400 mm²/s (20 – 400 cSt)
  • Operating Temperature Range: 0 – 60 °C
  • Fluid Contamination Control: The contamination level should be within NAS 10
  • Suction Pressure Requirement: -16.7 kPa ~ 50 kPa (-125 mmHg ~ +0.5 kgf/cm²)

5. Performance Characteristics

  • Efficiency: At 16 MPa (2320 psi) and 1800 r/min, the volumetric efficiency exceeds 98% and the overall efficiency exceeds 90%.
  • Step Response: The step response time (0 to maximum flow) is 5 ms, and the hysteresis is 2% or less (depending on the circuit and operating conditions).
  • Noise Performance: Advanced structural design ensures low noise operation, providing a quiet working environment.
  • Energy Saving: High overall efficiency effectively reduces power loss, minimizes oil temperature rise, and lowers the requirement for fuel tank capacity.

6. Safety & Usage Notes

  • When setting the pressure, ensure that the full cut-off pressure does not exceed the maximum intermittent pressure (28 MPa).
  • If the pump is operated above the rated pressure (25 MPa), the operating conditions are restricted: the intermittent time at maximum flow should not exceed 1/5 of one cycle time and 6 seconds simultaneously.
  • Avoid applying bending or radial loads to the pump shaft; the TIR of the drive shaft should not exceed 0.1 mm, and the angle deviation should not exceed 0.2°.
  • Ensure complete air bleeding of the pump and pipeline to avoid vibration caused by air entrapment.
  • When the pump is installed above the oil level, a foot valve should be installed in the suction pipeline, and the height from the suction port to the oil level should not exceed 1 m.
Note: All parameters are based on YUKEN official technical data sheets (references: Yuken Europe, Yuken Kogyo Co., Ltd.), and slight deviations may occur due to product upgrades or different operating conditions. For further details, please consult YUKEN official or authorized sales representatives.

yuken Variable Displacement Piston Pumps

A10-F-R-01-B-K-32
A10-FR07CS-12
A10-LR09DS-60
A100-FR01BS-60
A100-FR07CS-12
A100-LR09DS-60
A145-F-R-05EH-60
A145-FR01CK-32
A145-FR04BK-32
A145-LR01AS-60
A16-F-R-01-C-K-32
A16-FR01CK-32
A16-FR04BK-32
A16-LR01AS-60
A22-F-R-01-B-K-32
A22-FR01BS-60
A22-FR07CS-12
A22-LR09DS-60
A37-F-R-01-C-K-32
A37-FR01CK-32
A37-FR04BK-32
A37-LR01AS-60
A45-FR01BS-60
A45-FR07CS-12
A45-LR09DS-60
A56-FR01CK-32
A56-FR04BK-32
A56-LR01AS-60
A70-FR01BS-60
A70-FR07CS-12
A70-LR09DS-60
A90-FR01CK-32
A90-FR04BK-32
A90-LR01AS-60
AR16-FR01C-12
AR16-FR01C-22
AR16-FR01D-12
AR16-FR07C-22
AR16-LR01C-22
AR16-LR09C-22
AR22-FR01C-12
AR22-FR01C-22
AR22-FR01D-12
AR22-FR04C-22
AR22-LR01C-22
AR22-LR04C-22
AR37-FR01C-22
AR37-FR07C-22
AR37-LR01C-22
AR37-LR07C-22
ARL1-16-FR01C-22
ARL1-16-FR04C-22
ARL1-16-LR01C-22
ARL1-16-LR04C-22
ARL1-22-FR01C-22
ARL1-22-FR07C-22
ARL1-22-LR01C-22
ARL1-22-LR07C-22
ARL1-8-F-R-01-C-K-10
A7H180-FR01KK-10
A7H180-FR07KK-10
A7H180-FR09-11A4K-10
A7H180-LR01KK-10
A7H180-LR07KK-10
A3H100-FR01-11A4K-10
A3H100-FR07-11A4K-10
A3H100-FR09-11A4K-10
A3H116-FR01KK-10
A3H116-FR07KK-10
A3H145-FR01-11A4K-10
A3H145-FR01KK-10
A3H145-FR04KK-10
A3H145-FR07-11A4K-10
A3H145-FR09-11A4K-10
A3H16-FR01-11A4K-10
A3H16-FR01KK-10
A3H16-FR07-11A4K-10
A3H16-FR09-11A4K-10
A3H16-FR14KK-10
A3H16-LR01KK-10
A3H180-FR01-11A4K-10
A3H180-FR01KK-10
A3H180-FR07-11A4K-10
A3H180-FR07KK-10
A3H180-FR09-11A4K-10
A3H37-FR01-11A4K-10
A3H37-FR01KK-10
A3H37-FR07-11A4K-10
A3H37-FR07KK-10
A3H37-FR09-11A4K-10
A3H37-LR01KK-10
A3H56-FR01-11A4K-10
A3H56-FR01KK-10
A3H56-FR04KK-10
A3H56-FR07-11A4K-10
A3H56-FR09-11A4K-10
A3H56-LR01KK-10
A3H71-FR01-11A4K-10
A3H71-FR01KK-10
A3H71-FR07-11A4K-10
A3H71-FR07KK-10
A3H71-LR01KK-10
A3H90-FR01KK-10
A3H90-FR04KK-10
A3HG16-FR01KK-10
A3HG37-FR01KK-10
A3HG56-FR01KK-10
A3HG71-FR01KK-E1C-10
A3HG71-FR01KK-E1D-10
A3HG71-FR01KK-J1C-10
A3HG71-FR01KK-J1D-10
A3HG71-FR01KK-U1C-10
A3HG71-FR01KK-U1D-10
A3HG71-FR07KK-E1C-10
A3HG71-FR07KK-E1D-10
A3HG71-FR07KK-J1C-10
A3HG71-FR07KK-J1D-10
A3HG71-FR07KSP-E1C-10
A3HG71-FR07KSP-E1D-10
A3HG71-FR14KK-E1C-10
A3HG71-FR14KK-E1D-10
A3HG71-FR14KK-J1C-10
A3HG71-FR14KK-J1D-10
A3HG71-FR14KSP-E1C-10
A3HG71-FR14KSP-E1D-10
Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.