Vickers PVB10-FLSW-31-C-11 Piston Pump Specifications
Technical Parameters of Vickers Piston Pump PVB10-FLSW-31-C-11
1. Basic Information
-
Model: PVB10-FLSW-31-C-11
-
Brand: Vickers
-
Pump Type: Axial Piston Pump (Variable Displacement)
-
Series: PVB Series
-
Application: Industrial Hydraulic Systems, Heavy Machinery, Hydraulic Power Units
2. Core Performance Parameters
-
Displacement: 21.10 cm³/rev (1.29 in³/rev)
-
Maximum Operating Pressure: 210 bar (3000 psi) when using anti-wear hydraulic oil; 140 bar (2000 psi) when using water-glycol or water-in-oil emulsion
-
Maximum Shaft Speed: 3200 r/min (continuous operation)
-
Minimum Inlet Pressure: 0.8 bar (11.6 psi) (absolute pressure, to prevent cavitation)
-
Volumetric Efficiency: ≥95% (at rated pressure and speed)
-
Mechanical Efficiency: ≥90% (at rated pressure and speed)
3. Fluid Requirements
-
Fluid Type: Anti-wear hydraulic oil (ISO VG 32, 46, 68 recommended); Compatible with water-glycol and water-in-oil emulsion (40%/60%)
-
Fluid Temperature Range: -20°C to 80°C (-4°F to 176°F); Maximum intermittent temperature: 90°C (194°F)
-
Fluid Cleanliness: ISO 14644-1 Class 16/14 (NAS 8级); Recommended filtration: 10 μm absolute
-
Viscosity Range: 10 to 400 mm²/s (cSt) at operating temperature
4. Mounting & Shaft Specifications
-
Mounting Type: Flange Mounting (conforms to SAE standards)
-
Shaft Rotation: Clockwise (viewed from the shaft end); Left-hand rotation is available on request
-
Shaft End: Standard Design (y-type)
-
Shaft Diameter: 25.4 mm (1 inch) (SAE standard)
-
Swash Plate Movement: One side of center (pressure compensated models only)
5. Control & Adjustment
-
Control Type: Pressure Compensator (adjustable maximum displacement stop)
-
Pressure Compensator Range: 250 to 2000 psi (17.2 to 137.9 bar)
-
Control Design Number: 11 (standard configuration)
-
Port Configuration: Side Ports (w-type)
6. Physical & Environmental Parameters
-
Approximate Weight: 15 kg (33 lb)
-
Ambient Temperature Range: -20°C to 55°C (-4°F to 131°F)
-
Protection Class: IP54 (against dust and splashing water)
-
Material: Pump Housing – Cast Iron; Piston & Shaft – Alloy Steel
7. Standard Compliance & Notes
-
Compliance: Conforms to ISO 3019-2 and VDMA 24560-1 standards (for flange mounting)
-
Note 1: The maximum operating pressure and speed shall not be exceeded simultaneously to avoid premature wear.
-
Note 2: Regular maintenance of fluid cleanliness is essential to ensure the pump’s service life.
-
Note 3: All parameters are based on standard operating conditions; deviations may occur under special working environments.