Technical documentation for Vickers variable piston pumps
The following are official technical documents for the main series of variable displacement piston pumps fromEaton Vickers and Danfoss Vickers, including sample manuals, user guides, maintenance manuals, etc. They are sorted by series for quick reference.
I. Technical Documents for Mainstream Series
1. PVM Series Industrial / Mobile Variable Displacement Piston Pumps
Core Documents:
-
Chinese User Guide: Vickers by Danfoss PVM Variable Displacement Piston Pump Version B (BC484866735591zh-000101)
-
Continuous pressure up to 315bar, displacement 73.7/81cc/rev
-
Content: Product introduction, model coding, specification parameters, performance curves, installation and maintenance
-
Download: https://assets.danfoss.com/documents/latest/374310/BC484866735591zh-000101.pdf
-
-
English Technical Catalog: PVM Industrial Variable Displacement Piston Pumps (V-PUPI-TM007-E1)
-
Parameter of full PVM series (PVM018~PVM141)
-
Control options, performance data, dimension drawings
-
Download: https://pdf.directindustry.com/pdf/eaton-hydraulics/pvm-industrial-variable-displacement-piston-pumps/7323-527323.html
-
2. PVH Series High-Pressure Variable Displacement Piston Pumps
Core Documents:
-
Chinese Sample: PVH High-Flow High-Performance Pumps (gbc2010_c.pdf)
-
Open circuit design, rated pressure 280bar, intermittent pressure 320bar
-
Content: Product features, model description, performance parameters, installation dimensions
-
Download: http://www.vickers.sh.cn/pdfs/gbc2010_c.pdf
-
3. M Series Mobile Variable Displacement Piston Pumps
Core Documents:
-
Chinese Industrial Application Sample: M-Series Variable Displacement Piston Pumps (v-pp-mc-0004-c.pdf)
-
Axial piston design, continuous working pressure 280bar
-
Multiple controller options available for different working conditions
-
Download: http://vickershydraulic.com/site/pdfs/v-pp-mc-0004-c.pdf
-
-
Chinese Construction Machinery Application Sample: M-Series Construction Machinery Pumps (v-pp-mc-0003-c.pdf)
-
Open circuit design, high controller efficiency, reducing cooling requirements
-
Content: Product introduction, control options, performance curves, installation and maintenance
-
Download: http://www.eaton-vickers.cn/pdfs/v-pp-mc-0003-c.pdf
-
4. PVQ Series Quiet Variable Displacement Piston Pumps
Core Documents:
-
English Technical Manual: PVQ Piston Pumps (VICKERS_PVQ_pistones.pdf)
-
Quiet design, compatible with various hydraulic oils (mineral oil, synthetic oil, phosphate ester oil, etc.)
-
Supports thru-drive configuration, can be combined with other pumps
-
Content: Product characteristics, specification parameters, control methods, installation instructions
-
Download:https://ma-componentes.com/VICKERS_PVQ_pistones.pdf
-
5. PVB Series Variable Displacement Piston Pumps
Core Documents:
-
Chinese Sample: Axial Piston Pumps (Fixed and Variable Displacement) (gb2379b_c.pdf)
-
Covers models such as PVB5/6, PVB10/15, PVB20/29, PVB45, PVB90
-
Complies with DIN/ISO3019 standard, rated pressure 210bar
-
Download: http://www.vickershydraulic.com/site/pdfs/gb2379b_c.pdf
-
6. PVE Series Inline Variable Displacement Piston Pumps
Core Documents:
-
English Overhaul Manual: Eaton Vickers PVE12 Overhaul Manual
-
Detailed disassembly steps, component diagrams, maintenance specifications
-
Includes chapters on working principle, installation operation, performance testing, etc.
-
Download: https://www.manualslib.com/manual/41716/Eaton-Vickers-Pve12.html
-
II. Other Important Technical Documents
|
Document Name
|
Scope of Application
|
Core Content
|
Download Link
|
|
Vickers Hydrokraft TVW Closed Circuit Variable Displacement Piston Pump Manual
|
TVW Series
|
Closed circuit design, high-pressure applications
|
http://www.vickers.sh.cn/pumps_piston.htm
|
|
VVS/VVP Variable Vane Pump Maintenance Manual
|
VVS0/VVS1/VVS2/VVS3 VVP1/VVP2/VVP3
|
Spare parts list, compensator kit, maintenance steps
|
http://www.vickers.sh.cn/pdfs/V-PUVN-TP001-E.pdf
|
|
Eaton 420 Series Piston Pumps for Construction Machinery Sample
|
420 Series
|
Special for construction machinery, high-reliability design
|
http://www.vickers.sh.cn/pumps_piston.htm
|
III. Channels to Obtain Official Technical Documents
-
Eaton Vickers Official Website: http://www.eaton-vickers.cn/
-
Enter the “Product Center” → “Hydraulic Pumps” → “Piston Pumps” section to download Chinese samples
-
-
Danfoss Vickers Official Website: https://www.danfoss.com/en/products/hydraulics/vickers-by-danfoss/
-
Latest user guides and technical data for PVM series
-
-
ManualsLib: https://www.manualslib.com/
-
Provides maintenance manuals and operation guides for various Eaton Vickers models
-
-
Contact Eaton Vickers Technical Support Directly:
-
Obtain technical documents and professional support for specific models through the “Contact Us” section on the official website
-
IV. Tips for Using Technical Documents
-
Model Matching: Vickers variable displacement piston pump model coding is complex (e.g., PVH098R01AJ30A250000002001AB010A). Please find the corresponding document based on the complete model
-
Version Confirmation: Technical documents are updated regularly. It is recommended to download the latest version to obtain accurate parameters
-
Professional Terminology: Hydraulic professional terms in Chinese documents correspond to English (e.g., “变量控制” corresponds to “variable control”, “负载传感” corresponds to “load sensing”)
-
Safety Precautions: All operations and maintenance must strictly follow the safety specifications in the technical documents to avoid injury from high-pressure hydraulic oil
Do you need me to screen and provide the most matching official technical document download links and core parameter overview based on your specific Vickers variable displacement piston pump model (such as PVH/PVM/M/PVQ/PVB/PVE series)? Just tell me the complete model.