Company News

YUKEN PV2R quantitative low noise vane pump selection

YUKEN PV2R Series Low-Noise Fixed Displacement Vane Pump Complete Selection Catalog

1. Product Overview

The PV2R series is YUKEN Japan’s classic low-noise fixed displacement vane pump, consisting of single pumps (PV2R1 / PV2R2 / PV2R3 / PV2R4) and double pumps (PV2R12, PV2R13, PV2R14, PV2R23, PV2R24, PV2R34).

It adopts a special low-noise stator profile, featuring low pressure pulsation and stable operation. With a modular cartridge design, only the pump cartridge needs replacement for maintenance, lowering service costs. Widely applied in construction machinery pilot auxiliary pumps, injection molding machines, die-casting machines, forging machine tools and various hydraulic power units.

Unified technical specifications: Rated pressure 17.5 MPa, maximum peak pressure 21 MPa; Recommended speed 600~1800 rpm. Recommended fluid: ISO VG46 anti-wear hydraulic oil, fluid cleanliness NAS 8 or better.

2. PV2R Single Pump Series General Parameter Comparison Table

Series Displacement cc/rev Weight (Flange F) kg Weight (Foot L) kg Basic Displacement Sizes Typical Applications
PV2R1 5.8~30.1 9.0 11.2 6, 8, 10, 12, 14, 17, 19, 23, 25, 31 Pilot auxiliary pumps for construction machinery, small hydraulic stations, lubrication pumps
PV2R2 25.3~64.7 15.5 19.8 26, 33, 41, 47, 53, 59, 65 Injection molding machines, machine tools, medium-sized hydraulic stations; used as the large pump side of PV2R12 double pump
PV2R3 76.4~115.6 30.9 40.9 76, 94, 116 Large injection molding & die-casting machines, heavy-duty hydraulic stations; for PV2R13 / PV2R23 double pumps
PV2R4 136~237 68.5 93.5 136, 153, 184, 200, 237 Ultra-large flow heavy-duty hydraulic equipment; for PV2R14 / PV2R24 / PV2R34 double pumps

Mounting type: F = Flange mounting; L = Foot (base) mounting Rotation: R = Clockwise viewed from shaft end (standard); L = Counter-clockwise (custom version) Port: AA = Standard port; REA = Port position variant; Design No.: PV2R1(43), PV2R2(41), PV2R3(31), PV2R4(30)

3. PV2R Double Pump Combination Selection Table (shared drive shaft, 2 independent outlet oil circuits)

Double pump = small pump + large pump with two independent oil circuits. Ideal for combined supply of main circuit + pilot/control circuit, widely used in engineering and injection molding industries.

Double Pump Model Front Pump (Small Pump) Rear Pump (Large Pump) Weight (Flange) kg Weight (Foot) kg Typical Purpose
PV2R12 PV2R1: 6~31 cc/rev PV2R2: 26~65 cc/rev 25.0 29.3 Construction machinery, medium & small injection molding machines, main pump + pilot auxiliary pump (best-selling double pump on market)
PV2R13 PV2R1: 6~31 cc/rev PV2R3:76~116 cc/rev 45.6 55.6 Medium & large injection/die-casting machines, large-flow main circuit + small-flow control circuit
PV2R14 PV2R1: 6~31 cc/rev PV2R4:136~237 cc/rev 82.0 105.0 Heavy-duty equipment, ultra-large flow main pump + pilot control pump
PV2R23 PV2R2:26~65 cc/rev PV2R3:76~116 cc/rev 50.2 61.5 Dual medium-large flow for injection molding and forging machines with double actuator circuits
PV2R24 PV2R2:26~65 cc/rev PV2R4:136~237 cc/rev 90.5 118.0 Heavy-duty hydraulic stations, one medium flow and one ultra-large flow circuit
PV2R34 PV2R3:76~116 cc/rev PV2R4:136~237 cc/rev 102.5 131.0 Extra-large hydraulic systems, two independent large-flow oil circuits

Double Pump Model Code Example

PV2R13-12-76-F-RAA-43 PV2R13 (Combination of Series1+3) – Small pump displacement 12 – Large pump displacement76 – F Flange – R Clockwise – AA Port – Design No.43

4. Key Selection Guidelines (critical for customer selection)

  1. Pressure: Continuous operation ≤17.5 MPa; Short-time peak pressure max 21 MPa. Long-term full load at 21 MPa is not recommended, which will shorten cartridge service life.
  2. Speed: Min 750 rpm, Max 1800 rpm. For large displacement PV2R3 / PV2R4, avoid continuous high speed at 1800 rpm.
  3. Suction Requirements: Larger displacement requires higher standard for suction pipeline. PV2R3 & PV2R4 must adopt enlarged suction pipe, reduce elbows to prevent cavitation and abnormal noise.
  4. Hydraulic Oil: ISO VG46 anti-wear hydraulic oil with cleanliness NAS8 or higher. Impurities will rapidly wear vanes and stator.
  5. Rotation Confirmation: Standard rotation R (clockwise). If motor rotation is reversed, L counter-clockwise model must be selected. Never force reverse rotation of standard pumps.
  6. Replacement & Procurement: Original YUKEN and domestic replacement versions available on market. When replacing, verify flange dimension, shaft diameter, port position, displacement and rotation.
  7. Cartridge Spare Parts: Cartridge can be replaced separately for the whole series, no need to replace entire pump to reduce maintenance cost.

5. Quick Selection Guide

Working Condition Recommended Pump Type
Low flow, low pressure for pilot control & lubrication supply PV2R1 single pump / small pump side of PV2R12 double pump
Medium & small injection molding, machine tools, medium flow main circuit PV2R2 single pump / PV2R12 double pump
Large injection molding, die-casting, forging, medium-large flow main circuit PV2R3 single pump / PV2R13 / PV2R23 double pump
Heavy-duty hydraulic station, ultra-large flow equipment PV2R4 single pump / PV2R14 / PV2R24 / PV2R34 double pump
One large-flow main circuit + one small-flow pilot control circuit Prefer double pump PV2R12 / PV2R13