YUKEN 50T/150T Series Fixed Displacement Vane Pumps
YUKEN 50T and 150T series are low-noise fixed displacement single-stage vane pumps, designed with a pressure-balanced structure, and widely used as power sources in various hydraulic systems. The core differences between the two lie in the displacement range and application scenarios: the 50T is a small low-flow series, while the 150T is a medium medium-flow series.
I. Core Parameter Comparison Table
|
Parameters
|
50T Series
|
150T Series
|
Remarks
|
|
Displacement Range
|
7-36 cm³/rev (e.g., 50T-7 to 50T-36)
|
48-116 cm³/rev (e.g., 150T-48 to 150T-116)
|
Displacement determines flow rate
|
|
Maximum Working Pressure
|
21-28 MPa
|
28-40 MPa
|
Varies by specific model
|
|
Speed Range
|
800-2000 rpm
|
800-1800 rpm
|
Safe operation range
|
|
Noise Level
|
Below 65 dB (A)
|
Below 68 dB (A)
|
Smooth and quiet operation
|
|
Inlet/Outlet Size
|
3/4″ (Inlet), 1″ (Outlet)
|
1 1/4″ (Inlet), 1 1/2″ (Outlet)
|
Adapts to different flow requirements
|
|
Weight
|
Approx. 9-10.5 kg
|
Approx. 25-26 kg
|
Varies with displacement
|
II. Typical Model Specifications
1. Main Models of 50T Series
-
50T-07 (Displacement: 6.8 cm³/rev)
-
50T-12 (Displacement: 11.8 cm³/rev)
-
50T-17 (Displacement: 17.0 cm³/rev)
-
50T-23 (Displacement: 23.0 cm³/rev)
-
50T-26 (Displacement: 26.0 cm³/rev)
-
50T-36 (Displacement: 36.0 cm³/rev)
2. Main Models of 150T Series
-
150T-48 (Displacement: 48.0 cm³/rev)
-
150T-64 (Displacement: 64.0 cm³/rev)
-
150T-75 (Displacement: 75.0 cm³/rev)
-
150T-94 (Displacement: 93.6 cm³/rev)
-
150T-116 (Displacement: 115.6 cm³/rev)
III. Core Structure and Features
-
Pressure-Balanced Design: Adopts a double-acting balanced structure, with balanced radial force and low shaft load, extending service life.
-
Low-Noise Technology: Special vane design eliminates hydraulic oil eddy current, ensuring quiet, stable operation and high efficiency.
-
Compact Structure: Small in size, flange-mounted type can be directly connected to the motor, saving installation space.
-
Easy Maintenance: Simple structure, easy to disassemble and inspect, reducing maintenance costs.
-
Strong Versatility: Can work as a low-pressure vane pump in both high-pressure and low-pressure systems, adapting to various hydraulic circuits.
IV. Differences in Application Scenarios
Applications of 50T Series
-
Small precision machine tools, test benches
-
Medical equipment (small operating tables, imaging equipment)
-
Small injection molding machines, packaging machinery
-
Hydraulic control systems with low flow requirements
Applications of 150T Series
-
Construction machinery, die-casting machines, industrial machine tools
-
Medium/heavy medical equipment (large CT tables, heavy imaging tables)
-
Medium injection molding machines, hydraulic presses, automated production lines
-
Hydraulic power systems with high flow requirements
V. Explanation of Model Suffixes
The suffixes of 50T/150T series models indicate different configurations, for example:
-
F: Flange mounting method
-
R: Rotation direction (clockwise/counterclockwise)
-
L: Shaft extension type
-
S: Special seals
-
-10: Pressure level (10MPa)
For specific details, please refer to the official YUKEN catalog or technical manual.
VI. Maintenance Points
-
It is recommended to use ISO VG32-46 hydraulic oil with a cleanliness level of NAS Class 9 or higher.
-
Replace the filter element regularly (recommended every 2000 hours).
-
Avoid long-term operation under conditions exceeding 90% of the maximum pressure.
-
Ensure the pump is filled with hydraulic oil before starting to avoid dry operation.
-
Regularly check for noise, vibration and leakage, and perform maintenance in a timely manner.