news

PVH141 Series Axial Piston Pump Product Description

Vickers PVH141 series is a high-pressure variable displacement axial piston pump for open-circuit hydraulic systems. It is widely used in construction machinery, agricultural machinery, mining equipment, heavy-duty cranes and other mobile hydraulic systems. It supports load sensing, pressure compensation and constant power control. Nominal displacement is 141 cm³/rev. It features high volumetric efficiency, heavy-duty structure, low noise and good contamination tolerance, and can be matched with Eaton Vickers sectional valves and proportional valves.

Parameter legend

Code Explanation
QIC Load-sensing + pressure compensator, 350 bar class
AIC Pressure compensator only (constant pressure), 350 bar class
BIC Constant power / torque limiting, 320 bar class
RSF Right rotation, side port arrangement
LSF Left rotation, side port arrangement
10S SAE spline shaft
02S Keyed shaft
10 / 11 / 20 / 21 Compensator spring setting (standby & LS differential)
C25 NBR seal, standard temperature
C21 FKM (Viton) seal, high temperature
31 SAE 4-bolt flange, side ports
32 SAE 4-bolt flange, rear ports
41 ISO 4-bolt mounting flange

PVH141 Model Table

Complete Model Number Disp. (cm³/rev) Rated Press. (bar) Peak Press. (bar) Max Speed (rpm) Shaft
PVH141QIC-RSF-10S-10-C25-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-11-C25-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-20-C25-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-21-C25-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-10-C25-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-11-C25-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-20-C25-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-21-C25-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-10-C25-41 141 350 420 1850 Spline
PVH141QIC-RSF-10S-11-C25-41 141 350 420 1850 Spline
PVH141QIC-RSF-10S-20-C25-41 141 350 420 1850 Spline
PVH141QIC-RSF-10S-21-C25-41 141 350 420 1850 Spline
PVH141QIC-RSF-02S-10-C25-31 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-11-C25-31 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-20-C25-31 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-21-C25-31 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-10-C25-32 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-11-C25-32 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-20-C25-32 141 350 420 1650 Keyed
PVH141QIC-RSF-02S-21-C25-32 141 350 420 1650 Keyed
PVH141QIC-LSF-10S-10-C25-31 141 350 420 1850 Spline
PVH141QIC-LSF-10S-11-C25-31 141 350 420 1850 Spline
PVH141QIC-LSF-10S-20-C25-31 141 350 420 1850 Spline
PVH141QIC-LSF-10S-21-C25-31 141 350 420 1850 Spline
PVH141QIC-LSF-10S-10-C25-32 141 350 420 1850 Spline
PVH141QIC-LSF-10S-11-C25-32 141 350 420 1850 Spline
PVH141QIC-LSF-10S-20-C25-32 141 350 420 1850 Spline
PVH141QIC-LSF-10S-21-C25-32 141 350 420 1850 Spline
PVH141QIC-LSF-02S-10-C25-31 141 350 420 1650 Keyed
PVH141QIC-LSF-02S-11-C25-31 141 350 420 1650 Keyed
PVH141QIC-LSF-02S-20-C25-31 141 350 420 1650 Keyed
PVH141QIC-LSF-02S-21-C25-31 141 350 420 1650 Keyed
PVH141QIC-RSF-10S-10-C21-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-11-C21-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-20-C21-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-21-C21-31 141 350 420 1850 Spline
PVH141QIC-RSF-10S-10-C21-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-11-C21-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-20-C21-32 141 350 420 1850 Spline
PVH141QIC-RSF-10S-21-C21-32 141 350 420 1850 Spline
PVH141AIC-RSF-10S-10-C25-31 141 350 400 1850 Spline
PVH141AIC-RSF-10S-11-C25-31 141 350 400 1850 Spline
PVH141AIC-RSF-10S-20-C25-31 141 350 400 1850 Spline
PVH141AIC-RSF-10S-21-C25-31 141 350 400 1850 Spline
PVH141AIC-RSF-10S-10-C25-32 141 350 400 1850 Spline
PVH141AIC-RSF-10S-11-C25-32 141 350 400 1850 Spline
PVH141AIC-RSF-10S-20-C25-32 141 350 400 1850 Spline
PVH141AIC-RSF-10S-21-C25-32 141 350 400 1850 Spline
PVH141BIC-RSF-10S-10-C25-31 141 320 380 1650 Spline
PVH141BIC-RSF-10S-11-C25-31 141 320 380 1650 Spline

Technical Notes

  • Rated pressure is continuous working pressure; peak pressure is only for short shock load (≤10% duty cycle).
  • Recommended long-term working speed: 1300–1500 rpm to reduce heat and extend service life.
  • Minimum stable speed for load-sensing control: approx. 300 rpm.
  • Case drain pressure must be kept ≤ 2 bar continuously.
  • Theoretical flow: 141 cm³/rev, about 261 L/min at 1850 rpm.