YUKEN PV2R Series Vane Pump Technical Data
1. Product Overview
The YUKEN PV2R Series covers fixed-displacement vane pumps designed for industrial hydraulic systems. They feature low-noise operation, high-pressure performance and a broad flow selection. Single-pump and double-pump versions are both available, delivering stable and reliable performance for injection molding machines, hydraulic presses and a wide range of general industrial machinery.
2. Model Nomenclature
PV2R Series model coding follows the standard format below:PV2R[Series]-[Displacement]-[Mounting]-[Rotation]-[Port Position]-[Suffix]
| Component | Description |
|---|---|
| Series | PV2R1, PV2R2, PV2R3, PV2R4 (single pumps); PV2R12, PV2R13, PV2R23, PV2R24, PV2R33, PV2R34 (double pumps) |
| Displacement | Geometric displacement, unit: cm³/rev (e.g. 6, 14, 17, 25, 31, 41) |
| Mounting | F = Flange mounting; L = Foot mounting |
| Rotation | R = Clockwise; L = Counter-clockwise (viewed from shaft extension end) |
| Port Position | A = Standard; B = Optional |
| Suffix | Additional specifications (e.g. RAA, 43, 42) |
3. Key Technical Specifications
3.1 Performance Parameters (Single Pumps)
| Parameter | Value Range | Unit |
|---|---|---|
| Geometric Displacement | 5.8–237.0 | cm³/rev (mL/rev) |
| Maximum Operating Pressure | 21.0 (210 bar, 3050 psi) | MPa |
| Shaft Speed Range | 600–1800 (max intermittent 2000) | rpm |
| Ambient Temperature | −10 ~ +60 | °C |
| Fluid Temperature | 10 ~ 60 (intermittent peak 80) | °C |
| Viscosity Range | 20–400 | mm²/s (cSt) |
| Recommended Filtration | 10 | μm (ISO 4406 Class 16/13) |
3.2 Double Pump Specifications
- Two vane pump cartridges integrated inside one housing, sharing a common drive shaft
- Single suction port, two independent discharge ports
- Same maximum pressure rating of 21 MPa as single pumps
- Multiple displacement combinations available to satisfy flexible hydraulic circuit design
4. Structural Features & Advantages
- Low Noise Design: Optimized internal geometry and vane profile effectively reduce operational noise
- Cartridge Kit Construction: Core internal parts (rotor, vanes, cam ring and others) are assembled into one replaceable cartridge kit, simplifying maintenance and shortening downtime
- High Pressure Capability: Heavy-duty structure supports continuous operation up to 21 MPa (210 bar)
- Wide Flow Coverage: Displacement spans 5.8 cm³/rev to 237.0 cm³/rev to meet diversified system demands
- Bi‑Directional Rotation: Clockwise and counter-clockwise rotation options are available
- Multiple Mounting Options: Flange (F) and foot (L) mounting for flexible layout arrangement
- Wide Fluid Compatibility: Compatible with petroleum-based hydraulic oils, water-containing fluids (water-glycol, water-in-oil emulsion) and synthetic hydraulic fluids
5. Materials & Construction
- Rotor & Vanes: High-strength cast iron, precision machined for long service life
- Cam Ring: Case-hardened alloy steel for excellent wear resistance
- Pump Housing: Cast iron, high rigidity and good heat dissipation
- Shaft: High-tensile steel with precision ground surface
- Seals: Nitrile rubber (NBR) as standard; Viton (FKM) optional for high-temperature working conditions
6. Applications
- Injection molding machines
- Hydraulic presses
- Machine tools
- Plastic processing machinery
- Die-casting machines
- Construction machinery
- Material handling equipment
- General industrial hydraulic systems requiring stable performance and low noise
7. Operating & Maintenance Guidelines
Fluid Requirements
- Use clean hydraulic fluid within the recommended viscosity range of 20–400 cSt
- Maintain fluid temperature at 10–60°C; intermittent peak temperature shall not exceed 80°C
- Apply 10 μm absolute filtration
Installation
- Secure the pump on a rigid base to suppress vibration
- Precise alignment of drive shaft; maximum allowable misalignment ≤0.1 mm
- Adopt flexible coupling for power transmission
- Select adequate suction pipe size and keep suction piping as short as possible
Start‑Up
- Fill the pump cavity with hydraulic oil before initial commissioning
- Prime the pump to evacuate air from the hydraulic circuit
- Start under low pressure and ramp up gradually to rated working pressure
Maintenance
- Periodically inspect fluid level, temperature and contamination status
- Replace cartridge kit at recommended intervals (typically 2000–3000 operating hours)
- Check seals and gaskets for leakage during routine maintenance
- Perform servicing in accordance with official YUKEN service procedures
8. Technical Documentation & Resources
- Single Pump Catalog: EIC-B-1002-0 (PV2R Series Single Pumps)
- Double Pump Catalog: Cat.B-Edit1C (PV2R Series Double Pumps)
- Operating Manual: Available from YUKEN regional offices
- Spare Parts List: Cartridge kits, seal sets and wearing components included
For detailed specification tables, performance curves and application engineering support, please refer to official YUKEN technical documents or contact your local YUKEN authorized distributor.