PVH81 Series Open-Circuit Axial Piston Pump
PVH81 Series Piston Pump — Model Table ith Pressure / Speed Data
Source basis: Eaton Vickers PVH81 frame size (81 cm³/rev nominal), open-circuit variable displacement. Parameters below follow the PVH standard coding logic (control code, shaft code, seal/pressure class, mounting code), so the same model number always maps to the same pressure–speed envelope.
Parameter legend
| Code | Meaning |
|---|---|
| QIC | Load-sensing (LS) + pressure compensator, 350 bar class |
| AIC | Pressure compensator only (constant pressure), 350 bar class |
| BIC | Constant-power / torque-limiting, 320 bar class |
| RSF / LSF | Right / left rotation, side ports (SAE flange) |
| 10S / 02S | Spline shaft (SAE C) / keyed shaft |
| 10 / 11 / 20 / 21 | Compensator spring setting (standby & LS differential, low → high) |
| C25 / C21 | NBR seal pack, 350 bar / FKM (Viton) seal pack, 350 bar, high-temp |
| 31 / 32 / 41 | SAE 4-bolt flange, side ports / SAE 4-bolt flange, rear ports / ISO 4-bolt mount |
Hot-selling model
| Model Number | Disp. (cm³/rev) | Rated Press. (bar) | Peak Press. (bar) | Max Speed (rpm) |
|---|---|---|---|---|
| PVH81QIC-RSF-10S-10-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-11-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-20-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-21-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-10-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-11-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-20-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-21-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-10-C25-41 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-11-C25-41 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-20-C25-41 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-21-C25-41 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-02S-10-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-11-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-20-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-21-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-10-C25-32 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-11-C25-32 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-20-C25-32 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-02S-21-C25-32 | 81 | 350 | 420 | 2000 |
| PVH81QIC-LSF-10S-10-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-11-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-20-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-21-C25-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-10-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-11-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-20-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-10S-21-C25-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-LSF-02S-10-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-LSF-02S-11-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-LSF-02S-20-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-LSF-02S-21-C25-31 | 81 | 350 | 420 | 2000 |
| PVH81QIC-RSF-10S-10-C21-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-11-C21-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-20-C21-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-21-C21-31 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-10-C21-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-11-C21-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-20-C21-32 | 81 | 350 | 420 | 2200 |
| PVH81QIC-RSF-10S-21-C21-32 | 81 | 350 | 420 | 2200 |
| PVH81AIC-RSF-10S-10-C25-31 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-11-C25-31 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-20-C25-31 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-21-C25-31 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-10-C25-32 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-11-C25-32 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-20-C25-32 | 81 | 350 | 400 | 2200 |
| PVH81AIC-RSF-10S-21-C25-32 | 81 | 350 | 400 | 2200 |
| PVH81BIC-RSF-10S-10-C25-31 | 81 | 320 | 380 | 2000 |
| PVH81BIC-RSF-10S-11-C25-31 | 81 | 320 | 380 | 2000 |
Notes on pressure & speed
- Rated (continuous) pressure: 320–350 bar depending on control class; LS/compensator versions allow the full 350 bar continuously.
- Peak pressure: 380–420 bar, short-duration only (≤10 % of duty cycle). Never use peak as a design setting.
- Max speed is the mechanical limit at rated pressure; at 350 bar continuous the recommended working speed is 1800–2000 rpm to control case drain and oil temperature.
- Minimum speed for stable LS control: approx. 300 rpm (below that, LS response becomes sluggish).
- Case drain pressure must stay ≤ 2 bar (0.2 MPa) at all times; exceed it and the shaft seal and compensator behaviour are affected.
- Speed × displacement gives theoretical flow: 81 cm³/rev → approx. 178 L/min at 2200 rpm, 146 L/min at 1800 rpm.