Company News

YUKEN PV2R Series Single Pump Displacement Summary

PV2R Series Single Pump

Parameters sorted for YUKEN PV2R series for reference in product selection.
Pressure: Rated 17.5 MPa / Peak 21 MPa; Fluid: 46# anti-wear hydraulic oil, cleanliness NAS 8 or better

1. General Parameters by Series

Series Displacement Range cc/rev Rated Pressure MPa Peak Pressure MPa Recommended Speed rpm Max Speed rpm Flange (F) Weight kg Foot (L) Weight kg
PV2R1 6~31 17.5 21 750~1800 1800 9.0 11.2
PV2R2 26~65 17.5 21 600~1800 1800 15.5 19.8
PV2R3 76~116 17.5 21 600~1800 1800 30.9 40.9
PV2R4 136~237 17.5 21 600~1800 1800 68.5 93.5

2. Detailed Parameter List for Each Model

Flow calculated at 1450 rpm (Q=displacement×1450/1000, L/min); Estimated shaft power under rated pressure (η≈0.9)

Series Nominal Displacement cc/rev Actual Displacement cc/rev Rated Pressure MPa Peak Pressure MPa Recommended Speed rpm
PV2R1 6 5.8 17.5 21 750~1800
PV2R1 8 8.0 17.5 21 750~1800
PV2R1 10 9.4 17.5 21 750~1800
PV2R1 12 12.2 17.5 21 750~1800
PV2R1 14 13.7 17.5 21 750~1800
PV2R1 17 16.6 17.5 21 750~1800
PV2R1 19 18.7 17.5 21 750~1800
PV2R1 23 22.1 17.5 21 750~1800
PV2R1 25 24.6 17.5 21 750~1800
PV2R1 31 30.1 17.5 21 750~1800
PV2R2 26 25.3 17.5 21 600~1800
PV2R2 33 32.3 17.5 21 600~1800
PV2R2 41 41.3 17.5 21 600~1800
PV2R2 47 47.2 17.5 21 600~1800
PV2R2 53 52.5 17.5 21 600~1800
PV2R2 59 58.1 17.5 21 600~1800
PV2R2 65 64.7 17.5 21 600~1800
PV2R3 76 76.4 17.5 21 600~1800
PV2R3 94 93.6 17.5 21 600~1800
PV2R3 116 115.6 17.5 21 600~1800
PV2R4 136 136 17.5 21 600~1800
PV2R4 153 153 17.5 21 600~1800
PV2R4 184 184 17.5 21 600~1800
PV2R4 200 200 17.5 21 600~1800
PV2R4 237 237 17.5 21 600~1800

3. Parameter Notes

  1. Flow Formula: Q(L/min) = Displacement(cc/rev) × Speed(rpm) ÷ 1000. Table calculated at 1450 rpm (common 4-pole motor).
  2. Estimated Power Formula: P(kW) = 17.5MPa × Q(L/min) ÷ (60 × η), η≈0.9. This is shaft power at full rated pressure. Recommend adding 10%~15% safety margin for motor selection.
  3. Pressure: 17.5 MPa rated for continuous operation; 21 MPa is only for short peak pressure, NOT for continuous duty.
  4. Speed: PV2R1 minimum recommended speed 750 rpm for adequate suction. PV2R3/PV2R4 large displacement models should NOT run continuously above 1800 rpm to avoid overheating and excessive noise.
  5. Weight: Same pump body shared for all displacements within one series, hence identical weight. PV2R4 has heavy weight; mounting base must have sufficient rigidity.