Berarma hydraulic pump 02-PSP-1-16- FHRM
1. Model Code Interpretation
|
Code Segment
|
Meaning
|
Description
|
|---|---|---|
|
02
|
Series Code
|
Represents Berarma standard pump series with universal mounting dimensions for the same series
|
|
PSP
|
Product Series
|
Hydraulic compensation variable displacement vane pump (distinguished from PLP mechanical compensation and PVS dual compensation)
|
|
1
|
Size Class
|
Size 1, which is linked to displacement and working pressure
|
|
16
|
Geometric Displacement
|
16 cm³/rev (displacement per revolution, core selection parameter)
|
|
F
|
Connection Type
|
Flange mounting (G = Thread, S = Bushing)
|
|
H
|
Sealing Type
|
High-pressure seal, suitable for 160bar (default configuration)
|
|
R
|
Rotation Direction
|
Clockwise (viewed from the shaft end; R = Right, L = Left)
|
|
M
|
Special Configuration
|
Standard configuration (K = Pressure cut-off, Q = Flow limitation)
|
2. Core Performance Parameters
|
Parameter Item
|
Specification Value
|
Remarks
|
|---|---|---|
|
Geometric Displacement
|
16 cm³/rev
|
Core parameter for flow calculation
|
|
Maximum Flow Rate (at 1450 rpm)
|
23 L/min (6.07 US gpm)
|
Indicative value under standard conditions
|
|
Maximum Working Pressure
|
160 bar (2321 psi)
|
Stable operation under medium pressure conditions
|
|
Allowable Speed Range
|
800 ~ 1800 rpm
|
Recommended rated speed: 1450 rpm; flow decreases significantly below 800 rpm
|
|
Control Oil Pressure
|
0.8 ~ 1.6 MPa
|
Necessary for hydraulic compensation; flow ≥ 0.5 L/min
|
|
Volumetric Efficiency
|
High (specific value refers to official datasheet)
|
Affected by working pressure and oil temperature
|
|
Maximum Noise Level
|
≤ 76 dB(A)
|
Measured 1 meter away from the pump on Berarma test bench with flexible coupling
|
|
Weight
|
3.5 kg
|
Including motor bracket, excluding motor
|
3. Installation & Interface Parameters
|
Parameter Item
|
Specification Value
|
Remarks
|
|---|---|---|
|
Mounting Type
|
Flange Mounting
|
Complies with UNI ISO 3019/2 standard
|
|
Suction Port
|
G 1″
|
Recommended hard pipe; length ≤ 1.5m; equipped with 100μm coarse filter
|
|
Discharge Port
|
G 3/4″
|
Pressure resistance ≥ 21MPa; select pipe diameter according to flow rate
|
|
Drain Port
|
G 3/8″
|
Must be connected to the oil tank separately; do not connect to the return oil main pipe
|
|
Control Oil Interface
|
G 1/8″
|
Side compensation oil port, connected to independent oil circuit
|
4. Medium & Environmental Requirements
|
Parameter Item
|
Specification Value
|
Remarks
|
|---|---|---|
|
Hydraulic Oil Type
|
HM/HLP 32~46 anti-wear hydraulic oil
|
Complies with ISO 6743/4 and ISO 3448 (ISO VG 32 at 50℃)
|
|
Oil Viscosity Range
|
10 ~ 100 cSt
|
Affects pump efficiency and service life
|
|
Operating Oil Temperature
|
10 ~ 60℃
|
Inlet oil temperature ≤ 50℃; maximum allowable temperature ≤ 70℃
|
|
Compensation Temperature
|
-10 ~ 70℃
|
Ensures stable performance of the compensation mechanism
|
5. Notes
-
All parameters are measured under standard conditions: 1450 rpm, HM hydraulic oil (ISO VG 32), 50℃ oil temperature.
-
Pressure peaks exceeding 30% of the maximum operating pressure must be eliminated by appropriate measures.
-
The drain port must be connected independently to avoid back pressure affecting pump performance.
-
Regular maintenance of hydraulic oil cleanliness is recommended to extend the pump’s service life.