1. General Specifications (All Sizes Summary Table)
| Model | Geometric displacement (cm³/rev) | Min. adjustable displacement (cm³/rev) | Rated continuous pressure | Intermittent peak pressure | Speed range (r/min) | Approx. weight Flange / Foot mount (kg) |
|---|---|---|---|---|---|---|
| A3HG16 | 16.3 | 8.0 | 31.5 MPa | 35 MPa | 600 ~ 3600 | 17.0 / 21.0 |
| A3HG37 | 37.1 | 16.0 | 31.5 MPa | 35 MPa | 600 ~ 2700 | 26.5 / 34.0 |
| A3HG56 | 56.3 | 35.0 | 31.5 MPa | 35 MPa | 600 ~ 2500 | 34.5 / 43.0 |
| A3HG71 | 70.7 | 45.0 | 31.5 MPa | 35 MPa | 600 ~ 2300 | 45.0 / 52.0 |
| A3HG100 | 100.5 | 63.0 | 31.5 MPa | 35 MPa | 600 ~ 2100 | 56.5 / 83.5 |
| A3HG145 | 145.2 | 95.0 | 31.5 MPa | 35 MPa | 600 ~ 1800 | 68.5 / 88.0 |
| A3HG180 | 180.0 | 125.0 | 31.5 MPa | 35 MPa | 600 ~ 1800 | 85.0 / 106.0 |
Common General Parameters
| Item | Specification |
|---|---|
| Recommended fluid | Anti‑wear mineral hydraulic oil ISO VG32 / VG46 |
| Operating viscosity | 20 ~ 400 mm²/s |
| Fluid temperature | 0 ~ 60 ℃ |
| Fluid cleanliness | ISO 4406:18/15 or better (NAS 9) |
| Suction pressure | -16.7 ~ +50 kPa (600–1800 rpm); 0 ~ +50 kPa (>1800 rpm, vacuum forbidden) |
| Case drain pressure | Normal ≤0.1 MPa; transient peak ≤0.5 MPa |
| Standard seal | FKM fluorocarbon seal (for mineral oil) |
| Optional seal | Special seal kit for water‑glycol, phosphate ester fire‑resistant fluid |
2. Model Code Definition
A3HG □□‑ [F/L] [R/L] [01/07/09/14] [K/S]‑[E1/E2/U1/U2]‑10
-
A3HG = Series
-
□□ = Frame size (16/37/56/71/100/145/180)
-
F: Flange mount; L: Foot mount
-
R: Clockwise (view from shaft end); L: Counter‑clockwise
-
Control code
-
01: Pressure compensator (standard pressure cut‑off)
-
07: External pilot pressure compensator (remote pressure setting)
-
09: External pilot constant power control (power limiting, anti‑overload)
-
14: Load Sensing (LS) energy‑saving control
-
-
K: Keyed shaft; S: Splined shaft (shock load)
-
E1/E2: ISO flange; U1/U2: SAE flange
-
10: Design revision
3. Control Function Description
- 01 Pressure compensatorMaintain preset system pressure. When pressure reaches setting value, pump automatically reduces displacement to reduce flow and save power. Most widely used for injection machine, hydraulic press.
- 07 External pilot pressure compensatorPump cut‑off pressure is controlled remotely by external pilot relief valve, suitable for multi‑stage pressure circuits.
- 09 External pilot constant power controlPump input power is limited. Pressure rises → displacement reduces automatically to avoid motor overload. Power curve can be remote adjusted, for die casting & heavy press.
- 14 Load Sensing (LS)Pump only supplies the flow required by actuators, keep constant differential pressure between LS signal and pump outlet. Minimise heat and power loss for multi‑action machines.
4. Typical Applications
Injection moulding machines, hydraulic presses, die casting machines, metal bending & forming equipment, heavy machine tools, metallurgical auxiliary machinery, high‑flow hydraulic power packs, hydraulic test benches, energy‑saving retrofitting projects.
5. Installation & Start‑up Instruction
- Mount horizontally, fill port upward, use flexible coupling. Shaft runout ≤0.1 mm, angular misalignment ≤0.2°.
- Suction line: short, large bore, avoid air pocket. Suction filter ≥100 μm.
- Drain line must be submerged below oil level, drain pipe length less than 1 m.
- Pre‑fill pump housing with clean hydraulic oil before first start to avoid dry running damage.
- For tandem pump: the secondary pump displacement cannot exceed through‑drive shaft load rating.
- Adjustment rule:
-
Pressure screw clockwise → pressure rise
-
Flow screw clockwise → displacement / flow reduce
-
Lock nut must be tightened after adjustment
-
6. Maintenance & Trouble Shooting
Maintenance Schedule
-
Daily: Check oil level, noise, leakage, oil temperature
-
500h: Check filter element
-
2000h: Replace hydraulic oil and filter
-
6000~8000h: Overhaul pump, replace seal kit
Troubleshooting
| Symptom | Possible Cause |
|---|---|
| Cavitation, knocking noise | Low oil level, blocked suction filter, air ingress, too high oil viscosity |
| No pressure build‑up | Wrong regulator setting, internal wear, broken seal |
| Oil overheating | Continuous overload, poor cooling, contaminated oil, high drain pressure |
| External leakage | Damaged FKM seals, scratched mating surface |
7. Safety Notes
-
Release all system pressure and cut power before disassembly or adjustment.
-
Do not run continuously above 31.5 MPa; 35 MPa only for short shock.
-
Dry running will destroy pump in a short time.
-
Pump housing and pipeline can reach high temperature, avoid direct touch.
-
Install safety relief valve on pressure outlet circuit.
8. Hot‑selling Model Index
You already have separate 50‑model tables for A3HG37 / A3HG56 / A3HG71 / A3HG100 / A3HG145.
If you need, I can add A3HG16 and A3HG180 50 hot models in the same table format, or merge all series (16~180) into one unified catalog file for quotation.