news

YUKEN Variable Displacement Piston Pump (A Series)

YUKEN Variable Displacement Piston Pump (A Series) Technical Document

Original official Yuken English catalogue abstract (A series swash plate axial variable piston pump, the mainstream Yuken variable piston pump)

1. General Description

YUKEN A series pumps are swash plate type axial variable displacement piston pumps, featuring high efficiency, low noise and low heat generation. Multiple control versions are available: pressure compensator, constant power, load sensing, proportional electro-hydraulic pressure & flow control, etc. Widely used in injection molding machines, presses, machine tools and general industrial hydraulic systems.

2. Main Features

  • High efficiency: Volumetric efficiency ≥98%, overall efficiency ≥90% (16 MPa, 1800 r/min)

  • Low noise: A16 can reach 57.3 dB(A) (1 m distance, 21 MPa, 1500 r/min)

  • Sharp cut-off characteristic, energy saving and low temperature rise

  • Wide displacement lineup: A10 / A16 / A22 / A37 / A56 / A70 / A90 / A100 / A145

  • Multiple control options, optional through-drive for tandem pump assembly

3. Model Nomenclature Example

A16-F-R-01-B-S-K-32

  • A16: Series, displacement 15.8 cm³/rev

  • F: Flange mounting; L = Foot mounting

  • R: Rotation (clockwise viewed from shaft end)

  • 01: Pressure compensator control type

  • B: Pressure adjustment range

  • S: Side port (blank = axial port)

  • K: Keyed shaft

  • 32: Design number

4. Main Specifications (Pressure Compensator Type)

Model Geometric Displacement cm³/rev Min. Adjustable Flow cm³/rev Rated Pressure MPa Intermittent Max. Pressure MPa Speed Range r/min
A10 10.0 2.0 16 21 600–1800
A16 15.8 4.0 16 21 600–1800
A22 22.2 6.0 16 21 600–1800
A37 36.9 10.0 16 21 600–1800
A56 56.2 12.0 16 21 600–1800
A70 70.0 30.0 25 28 600–1800
A90 91.0 56.0 25 28 600–1800
A100 100.0 62.0 21 21 600–1800
A145 145.0 83.0 25 28 600–1800

5. Hydraulic Fluid Requirements

  • Recommended oil: Anti-wear hydraulic oil, ISO VG32 / VG46

  • Viscosity range: 20 ~ 400 cSt

  • Operating oil temperature: 0 ~ 60 °C

  • Contamination level: NAS 10 or better; 10 μm return filter or offline filtration is required

6. Installation & Piping

  1. Shaft coupling: Use flexible coupling; TIR misalignment ≤ 0.1 mm, angular misalignment ≤ 0.2°
  2. Suction condition: Permissible suction pressure −16.7 ~ +50 kPa; oil level height difference ≤1 m
  3. Drain line: Case pressure normal <0.1 MPa, surge <0.5 MPa; drain pipe submerged in oil, length ≤1 m
  4. Pre-fill oil: Fill pump housing with clean oil before initial start-up
  5. Air bleeding: Bleed air from pump casing and discharge line to avoid vibration and noise

7. Adjustment Instructions

  • Pressure screw: Clockwise → pressure increase; lock after setting

  • Flow/delivery screw: Clockwise → flow decrease; lock after setting

  • Factory preset: Maximum flow, minimum pressure

8. Control Types Summary

  • 01: Pressure compensator (constant pressure)

  • 02: Unloading pressure compensator

  • 03: Two-pressure solenoid control

  • 04E: Proportional electro-hydraulic load sensing

  • 04EH: Proportional pressure & flow control (OBE)

  • Constant power control, load sensing control optional

9. Notes

  • Intermittent high-pressure working time is limited; do not exceed cut-off pressure

  • When tandem pump (A37~A145), consult Yuken for through-drive specifications

  • A7H series is high-pressure version (rated 35 MPa, max 40 MPa) for heavy-duty applications